dev 03dda1245a spec: single normative source, accept RFC 0004, freeze AIR format 0, fuel
Owner decisions after the Phase 0 review:

- precedence: docs/spec/ is the single normative source; RFCs are
  decision records whose accepted rules are integrated into the spec in
  the same change (AGENTS.md, docs/README.md, rfcs/README.md, DD-011)
- RFC 0004 Accepted (scope: AIR format 0, language 0.1)
- AIR format 0 frozen as the semantic baseline; spec 07 §8.7 defines the
  only permitted additive changes, everything else needs `air 1` (DD-012)
- Q-019 resolved: deterministic instruction fuel (spec 11 §7). Outcome
  `limit_exceeded` is a runner outcome, not a trap; `aji run --fuel N`,
  exit code 5; conformance runs always use fuel (default 1 000 000,
  `fuel:` header); fuel/schedule budget/quantum kept separate for P3
  (DD-013)
2026-10-04 12:40:32 +03:00

7.1 KiB

07. AIR — Aji Intermediate Representation

1. Role

AIR is the canonical semantic representation of Aji.

Source syntax is optional tooling. AIR is mandatory for conformance.

AIR is:

  • typed;
  • SSA-oriented;
  • basic-block based;
  • explicit about ownership and borrows;
  • explicit about effects and capabilities;
  • explicit about synchronization;
  • deterministic to parse and verify.

2. Functions and blocks

Illustrative AIR:

fn @sum(%a: u64, %b: u64) -> u64
effects []

entry:
    %0 = add.checked.u64 %a, %b
    ret %0

Blocks receive values through block parameters rather than implicit phi nodes:

br @loop(%next)

loop(%i: u64):
    ...

3. Core instruction classes

Values and arithmetic

const
copy
move
add.checked
sub.checked
mul.checked
div.checked
add.wrap
sub.wrap
mul.wrap
and or xor
shl shr
eq ne lt le gt ge

Control flow

br
cbr
switch
ret
trap
guard
assert

Borrowing and memory

borrow.ref
borrow.mut
borrow.end
load
store
mem.copy
mem.zero
slice.make
slice.sub

Ownership

own.alloc
own.free
region.create
region.alloc
region.alloc_uninit
region.reset
region.destroy
island.create
island.alloc
island.freeze
arc.clone
arc.release

Calls

call
call.indirect
intrinsic.call

Concurrency

task.scope.begin
task.scope.end
task.spawn
task.join
task.cancel
thread.spawn
thread.join
channel.send
channel.recv
mutex.lock
mutex.unlock
rwlock.read
rwlock.write
atomic.load
atomic.store
atomic.rmw
atomic.cmpxchg
atomic.fence

4. Instruction contract

Every AIR instruction definition must specify:

  • operand types;
  • result types;
  • ownership-state transition;
  • borrow-state transition;
  • memory reads/writes;
  • synchronization effects;
  • effect requirements;
  • capability requirements;
  • trap behavior;
  • verifier transfer function.

5. No hidden semantics

AIR does not contain:

  • hidden destructors;
  • implicit allocation;
  • implicit exception edges;
  • default memory orderings;
  • implicit task detachment.

6. Serialization

Canonical AIR should have both text and binary forms.

Binary AIR conceptually contains:

HEADER
TYPE_TABLE
CONSTANT_TABLE
CAPABILITY_TABLE
FUNCTION_TABLE
BLOCK_TABLE
INSTRUCTION_STREAM
CONTRACT_TABLE
DEBUG_TABLE

Every binary must encode version and required feature bits.

7. Verification before execution

Native code must not be produced from unverified safe AIR.

Unsafe AIR modules are allowed only through explicit trusted/unsafe boundaries and must appear in the unsafe dependency report.

8. Text AIR, format version 0

The grammar is ../reference/air-text.ebnf. Instruction semantics are in 07a-air-instructions.md.

8.1 Module header

Every text module MUST begin with:

module <path>
air 0
lang 0.1
features []

An implementation MUST reject a module whose air format version or lang version it does not implement (E0005), and a module that lists a feature it does not implement (E0006). Format version 0 defines no features.

8.2 Functions and blocks

  • A function body is a non-empty sequence of blocks. The first block is the entry block; it MUST NOT declare parameters. Function parameters are in scope in the entry block and every block it dominates.
  • Every block MUST contain at least one instruction, MUST end with exactly one terminator, and MUST NOT contain a terminator before its last instruction (E5002).
  • A branch target MUST name a block of the same function and pass exactly as many arguments as the block declares parameters (E5002). Argument binding is simultaneous: all arguments are read before any parameter is written.
  • Every %name MUST be defined exactly once per function, as a function parameter, a block parameter or an instruction result (E5001). Every use MUST be dominated by its definition (E5001); a use in the same block MUST come after the defining instruction. Uses in blocks unreachable from the entry block are only checked within their own block.
  • Function and type names MUST be unique within a module, and block labels within a function (E0003). Field names MUST be unique within a struct and variant names within an enum (E0003).

8.3 Types

  • Integer types, bool, void and never are built in. usize/isize are distinct from all fixed-width types; their width comes from the target description (spec 09 §9).
  • type @T = struct { … } and type @T = enum { … } declare nominal aggregate types. An aggregate MUST NOT contain itself by value, directly or through other aggregates (E1003).
  • Every type defined in this section is copyable. Types added later under §8.7 (for example Own<T> in Phase 1) may be move-only or linear; that does not change the types defined here.
  • void is only valid as a function return type. A void function returns with ret without operand; a call to it MUST NOT bind a result. A never function MUST NOT contain ret.

8.4 Reserved

f32 and f64 are reserved until floating-point determinism is specified (open question Q-016). A module that uses them MUST be rejected with E0006.

8.5 Canonical form

The canonical serialization of a module is: the four header lines; one blank line; type declarations in declaration order, one per line; for each function, a blank line, the signature line, the effects line, then each block label at column 0 followed by its instructions indented by four spaces. Separators are ", " between list items and single spaces elsewhere. Comments are not preserved. Value, block, function and type names are preserved.

Serializing a parsed module and parsing the result MUST yield an equal module.

8.6 Diagnostic order

Verification stops after the first stage that reports an error, in this order: parsing and name resolution, resource limits, CFG structure, SSA, types. Within a stage, diagnostics are ordered by source position. The result is therefore deterministic for a given input.

8.7 Stability of format 0

Format 0 is the frozen semantic baseline of AIR (RFC 0004, Accepted). Its existing constructs keep their meaning for as long as air 0 exists.

A change is permitted under air 0 only if all of the following hold:

  1. every module accepted before the change is still accepted and produces the same run record (spec 07a "Run result") or the same trap record;
  2. every module rejected before the change is still rejected with the same codes, except where the rejection was E0004 (unknown opcode or type name) or E0006 (reserved type or unsupported feature) and the change gives that name a meaning;
  3. the change adds instructions, types, header features, diagnostic codes or trap codes, and specifies each new instruction in spec 07a before it is implemented;
  4. the canonical form (§8.5) of existing constructs is unchanged.

Any other change to format 0 — a different meaning, typing rule, trap behavior, diagnostic code or canonical spelling for an existing construct — requires a new format version (air 1) introduced by an RFC. An implementation that supports several format versions selects the semantics by the module's air line; it never mixes them.